Sail E0 Webinar

MCQs

Total Questions : 476 | Page 44 of 48 pages
Question 431. When the hardness and alkalinity are around 30% what should be used?
  1.    SAC
  2.    WAC
  3.    WAC, SAC
  4.    WAC, SAC, WBA
 Discuss Question
Answer: Option C. -> WAC, SAC
Answer: (c).WAC, SAC
Question 432. The treatment system includes a WAC, SAC, followed by a WBA and SBA. There is a degasser in this system. Calculate the amount of SBA resin required for the following data.
M Alkalinity: 100 ppm as CaCO₃
P Alkalinity: 100 ppm as CaCO₃
Silica: 30 ppm as CaCO₃
CO₂: 45 ppm as CaCO₃
EMA: 100 ppm as CaCO₃
Capacity: 37 Kg/m³
Correction factor: 0.9
Flow rate: 35 m³/hr
Operation hours: 10 hrs
  1.    0.5 m³
  2.    0.9 m³
  3.    1.9 m³
  4.    1.5 m³
 Discuss Question
Answer: Option A. -> 0.5 m³
Answer: (a).0.5 m³
Question 433. The treatment system includes a WAC, SAC, followed by a WBA and SBA. There is no degasser in this system. Calculate the amount of resin required for the following information.
M Alkalinity: 100 ppm as CaCO₃
P Alkalinity: 100 ppm as CaCO₃
Silica: 45 ppm as CaCO₃
CO₂: 45 ppm as CaCO₃
Capacity: 37 Kg/m³
Correction factor: 0.9
Flow rate: 35 m³/hr
Operation hours: 10 hrs
  1.    1.5 m³
  2.    1.1 m³
  3.    7.9 m³
  4.    7.5 m³
 Discuss Question
Answer: Option B. -> 1.1 m³
Answer: (b).1.1 m³
Question 434. The treatment system consists of a WAC, SAC which is followed by a WBA and SBA. Calculate the amount of WBA resin required for the following data.
M Alkalinity: 100 ppm as CaCO₃
P Alkalinity: 100 ppm as CaCO₃
EMA: 25 ppm as CaCO₃
Capacity: 37 Kg/m³
Correction factor: 0.9
Flow rate: 135 m³/hr
Operation hours: 20 hrs
  1.    2.5 m³
  2.    2.8 m³
  3.    1.2 m³
  4.    7.5 m³
 Discuss Question
Answer: Option C. -> 1.2 m³
Answer: (c).1.2 m³
Question 435. ________ is the removal of calcium, magnesium and certain other metal cations in hard water.
  1.    Disinfection
  2.    Sedimentation
  3.    Softening
  4.    Cleaning
 Discuss Question
Answer: Option C. -> Softening
Answer: (c).Softening
Question 436. Soft water can foul plumbing.
  1.    True
  2.    False
  3.    May be True or False
  4.    Can't say
 Discuss Question
Answer: Option B. -> False
Answer: (b).False
Question 437. What is the permitted concentration of manganese in drinking water?
  1.    30 g/l
  2.    40 g/l
  3.    50 g/l
  4.    60 g/l
 Discuss Question
Answer: Option C. -> 50 g/l
Answer: (c).50 g/l
Question 438. In which year was the Ferrosand process patented?
  1.    1960
  2.    1965
  3.    1970
  4.    1975
 Discuss Question
Answer: Option B. -> 1965
Answer: (b).1965
Question 439. What is the minimum time of aeration?
  1.    20 minutes
  2.    40 minutes
  3.    60 minutes
  4.    80 minutes
 Discuss Question
Answer: Option C. -> 60 minutes
Answer: (c).60 minutes
Question 440. What is the permitted concentration of iron in drinking water?
  1.    100 g/l
  2.    200 g/l
  3.    300 g/l
  4.    400 g/l
 Discuss Question
Answer: Option B. -> 200 g/l
Answer: (b).200 g/l

Latest Videos